Solar Cable

BE COMPLIANT AND SAFE
Specify SolarWire™ For Your Solar Projects

  • Philatron SolarWires Are PV UL Listed And NEC Compliant
  • High Quality Crosslinked Polyethlene (XLPE) Insulation.
  • Carry A Unique Multi-UL Rating: Types; XHHW2, SIS, And RHW2
  • Philatron (UL) (volts) (size) PV Wire or 600 Volts RHW-2/USE-2 90c Wet or Dry Sun Res-40C VW-1 RoHS
  • Available In Solid, Medium And Extra Flexible Copper Stranding
  • 14-4/0 AWG Meets UL 8.54 Type USE-2 Standard for Service Entrance Cables. 18-16 AWG Meets UL 66 Standard For Fixture Wire SEC 6
  • Abrasion, Oil, Flame, Heat, Ozone, Water, & Sun Resistant
  • 600, 1,000, & 2,000 Volts +90°C to -40°C Dry and Wet Indoors & Outdoors

PHILATRON CABLE & WIRE
Based in Southern California, since 1974, and with over 35 years in manufacturing, Philatron Wire and Cable leads the wire and cable industry in custom design and intelligent innovation. Please contact us at www.philatron.com , or, contactusnow@philatron.com

Part No. Size Strands Ins.
Wall
Mils
OD
Inch
Lbs
Mft
PV
600
Volts
PV
2000
Volts
600 Volts
RHW2
USE-2
PV186-#
PV182-#
PV166-#
PV162-#
18
18
16
16
16/.010
16/.010
19/.0177
19/.0117
.060
.075
.060
.075
.169
.204
.180
.215
14
16
18
21
Yes
No
Yes
No
No
Yes
No
Yes
No
No
No
No
PV146-#
PV142-#
PV126-#
PV122-#
14
14
12
12
19/.0142
19/.0142
19/.0185
19/.0185
.060
.075
.060
.075
.194
.229
.214
.248
27
32
36
42
Yes
No
Yes
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
PV106-#
PV102-#
PV086-#
PV082-#
10
10
8
8
19/.0234
19/.0234
19/.0295
19/.0295
.060
.075
.075
.085
.238
.278
.305
.325
51
57
80
87
Yes
No
Yes
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
PV066-#
PV062-#
PV046-#
PV042-#
6
6
4
4
19/.0372
19/.0372
19/.0469
19/.0469
.075
.085
.075
.085
.342
.375
.385
.445
115
123
170
181
Yes
No
Yes
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
PV026-#
PV022-#
PV016-#
PV012-#
2
2
1
1
19/.0526
19/.0526
19/.0664
19/.0664
.075
.085
.095
.105
.453
.500
.515
.600
253
266
333
350
Yes
No
Yes
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
PV1/06-#
PV1/02-#
PV2/06-#
PV2/02-#
1/0
1/0
2/0
2/0
19/.0740
19/.0740
19/.0837
19/.0837
.095
.105
.095
.105
.563
.655
.608
.710
410
429
502
527
Yes
No
Yes
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
PV3/06-#
PV3/02-#
PV4/06-#
PV4/02-#
3/0
3/0
4/0
4/0
19/.0940
19/.0940
19/.1055
19/.1055
.095
.105
.095
.105
.658
.760
.714
.820
620
647
620
796
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes

To specify color add # to end of part number: Black-1, White-2, Red-3, Green-4, Orange-5, Blue-6, Yellow-7. **Amps are based on the NEC Table 310.16 for 90°C (194°F) rated conductors at ambient temperature of 30°C(86°F).