PHILATRON
Specialists in Reliability

                                       

                               PHILAFIN
                                                                            (+125° C -65°C - Cross Linked Polyolifin Rubber)
                                                                                                           Test Report
 
                                                         PHILAFIN™ Provides Superior:
 
 
  • Oil Resistance

  • Low Temp Resistance

  • Heat Aging

  • Ozone Resistance

 

  • Chemical Resistance

  • Abrasion Resistance

  • Mechanical Strength

  • Lighter Weight

 

_________________________________________________________________________________________________________________________
  • LOWER TEMPERATURE FLEXIBILITY  

  • GREATER OZONE RESISTANCE

PHILAFIN™ rubber flexible cord jackets resist cracking to
lower temperatures than either thermoset Neoprene or
thermoset rubber. The following are results of bend tests:

Ozone as generated around most electrical equipment can
cause cracking in most conventional rubbers. PHILAFIN™
rubber has excellent resistance to cracking caused by ozone.
Below are results of bent loop ozone aging tests of flexible
cord jackets.

 
 

PHILAFIN

RUBBER

NEOPRENE

   

PHILAFIN

RUBBER

NEOPRENE

 

Type SEO

Type S

Type SO

   

Type SEO

Type S

Type SO

Cold Bend @ -35°C

Pass

Pass

Pass

Hours to Cracking

 

1,000

24

300

Cold Bend @ -50°C

Pass

Cracked

Cracked

 

 

 

 

 

Cold Bend @ -65°C

Pass

Cracked

Cracked

 

 

 

 

 

PHILAFIN™ cables & cords are UL rated at -50°C to +105°C.

NOTE: OZONE EXPOSURE - 100pphm/100°F

_________________________________________________________________________________________________________________________
  • SUPERIOR HEAT AGING

  • TOUGHER ABRASION RESISTANCE

PHILAFIN™ rubber resists cracking and brittleness caused
by heat far better than Neoprene or rubber. Comparative
heat aging at 250°F. is shown.

Shown below are comparative grinding wheel type abrasion
test results on flexible cord jackets. Again, PHILAFIN™
rubber outperforms Neoprene and rubber flexible cord
jackets.

Oven Aged at 7 Days @ 250F

CYCLES TO FAILURE

page 2 