STALLION 7 WAY SOCKET SYSTEMS
Designed to Eliminate Over-Heating & Corrosion Problems

socketfrontsmall.jpg (18214 bytes)                       socketsidesmall.jpg (19613 bytes)

STANDARD SIZE ABS SIZE MAXIMUM SIZE

Open Length
for Splicing

Cat. No. Cable Cat. No. Cable Cat. No. Cable
71210006 6/12 & 1/10 71008006 4/12, 2/10, 1/8 70806006 4/12, 1/10, 1/8, 1/6 .5 Foot
71210012 6/12 & 1/10 71008012 4/12, 2/10, 1/8 70806012 4/12, 1/10, 1/8, 1/6 1 Foot
71210018 6/12 & 1/10 71008018 4/12, 2/10, 1/8 70806018 4/12, 1/10, 1/8, 1/6 1.5 Feet
71210042 6/12 & 1/10 71008042 4/12, 2/10, 1/8 70806042 4/12, 1/10, 1/8, 1/6 3.5 Feet
71210072 6/12 & 1/10 71008072 4/12, 2/10, 1/8 70806072 4/12, 1/10, 1/8, 1/6 6 Feet
71210108 6/12 & 1/10 71008108 4/12, 2/10, 1/8 70806108 4/12, 1/10, 1/8, 1/6 9 Feet
71210144 6/12 & 1/10 71008144 4/12, 2/10, 1/8 70806144 4/12, 1/10, 1/8, 1/6 12 Feet
71210360 6/12 & 1/10 71008360 4/12, 2/10, 1/8 70806360 4/12, 1/10, 1/8, 1/6 30 Feet
71210480 6/12 & 1/10 71008480 4/12, 2/10, 1/8 70806480 4/12, 1/10, 1/8, 1/6 40 Feet
71210600 6/12 & 1/10 71008600 4/12, 2/10, 1/8 70806600 4/12, 1/10, 1/8, 1/6 50 Feet
71210720 6/12 & 1/10 71008720 4/12, 2/10, 1/8 70806720 4/12, 1/10, 1/8, 1/6 60 Feet

 

COLOR CODE CHART

 

 

IMPORTANT INFORMATION

Code Purpose smcc.jpg (14429 bytes)

Industry Max.

Stallion Max.
1 White Ground 8 AWG 6 AWG
2 Black Clearance, Marker & I.D. 12 AWG 12 AWG
3 Yellow Left Turn 12 AWG 12 AWG
4 Red Stop 10 AWG 10 AWG
5 Green Right Turn 12 AWG 12 AWG
6 Brown Tail 12 AWG 12 AWG
7 Blue Auxiliary & ABS 10 AWG 8 AWG
Prior to ABS requirements, the number 7 (blue) wire conductor was sized 12 AWG.  This circuit was intended for "auxiliary" purposes.

With ABS as law, DOT specified that the blud auxiliary circuit shall also be used for continuous power for ABS and the size was changed from 12 to 10 AWG.

However, many auxiliary devices plus the demands of the ABS have caused some trucks to experience overheating due to over-loading the amp capacity of the auxiliary blue wire conductor as well as the ground white wire conductor.

One of the purposes of the Stallion Power 7 Way socket is to give the industry the option of choosing a larger auxiliary blue conductor and a larger ground white conductor that will eleminate the over-loading and heating problem.

The chart at the left shows the Industry's maximum wire sizes vs. Stallion's maximum wire sizes for the auxillary/ABS and ground wires.

The Stallion 7 way socket is interchangeable and works with all standard SAE 560b plugs.

CLICK HERE FOR ZOOM IN PAGE OF THIS SECTION

 

Trucking Sales Department      (800)967-9147    Fax (413)502-8275  Email:  truckingdept@philatron.com

Back to Table of Contents